Telecast Fiber Shed and HDX
     Telecast HDX and Shed     

Telecast HDX-Front

Telecast Shed

The Telecast HDX and SHED allow the camera chain to send and receive video and data over simpler and cheaper ST Single Mode Fiber Cables,  Cables like TAC-12 can deliver up to 6 cameras over a single lower cost fiber optic path than SMPTE Fiber.  TAC Cables tend to be simpler to install and can be removed quicker and more efficiently than multiple sets of SMPTE fiber cables.

Daily Rental Rate

Weekly Rental Rate

Monthly Rental Rate

$200

$450

$950

What's Included:

1 Telecast Shed SMPTE to ST Adapter

1 Telecast HDX for Sony and Ikegami Cameras

Operator's Manual

1 Shipping Case

AC Cable

Manual

Telecast Shed and HDX for Sony and Ikegami Cameras

Operators Manual

Specifications

 Specifications - SHEDs

Environment
Dimensions (L x W x H) 7.5" x 1.9" x 2.5"
Weight 1 lb.
Temperature Range -20 C to +55 C
Humidity Range 0 to 95% non-condensing

Connectors
HYBRID (SMPTE) LEMO (SMPTE 304M) standard
Optical Two ST type, singlemode

Power Consumption
Base Station unit Less than 20 Watts
Camera unit Less than 20 Watts

Transmission
Transmission Method As determined by camera system
Fiber Types Single-Mode
Wavelength (from/to cam) 1300/1550 nm

Representative Fiber Specifications
Fiber Type Single Mode (SM) 9/125µ
Attenuation Factor 0.5 dB/km @ 1300 nm

Specifications - HDX

Environment
Dimensions (L x W x H) 13" x 3.4" x 8.4"
Weight 8.5 lbs.
Temperature Range -20 C to +55 C
Humidity Range 0 to 95% non-condensing

Connectors
HYBRID (SMPTE) LEMO (SMPTE 304M) standard
Optical Two ST type, singlemode

Input Voltage 100/120/240 VAC, Nominal, 47 - 63 Hz, 250 VA

Power Consumption 150 VA (120 VA available for camera ops,
viewfinder, lens, etc.)

Indicators LEDs: AC IN, DC HV Enable, AC HV Enable, HV
Present, Cable Open, Short Cable, Remote Pwr
Enable
4-Segment Display: “Load Type” and “Optical
Power”

Transmission
Transmission Method As determined by Camera System
Fiber Types Single-Mode
Link Margin/Distance 12 dB/20 km
Wavelength (from/to cam) 1300/1550 nm

Representative Fiber Specifications
Fiber Type Single Mode (SM) 9/125µ
Attenuation Factor 0.5 dB/km @ 1300 nm

   